Photodetector device

HYPERSPECTRAL SENSING

See the spectrum
Identify more information

Visible and near-infrared device options combine spectral acquisition, imaging and computational reconstruction for instrument integration.

01 / VISIBLE

Visible Hyperspectral Sensor

Spectral acquisition and imaging in the visible and extended wavelength range for water monitoring, color and feature recognition, and instrument front ends.

Synchronous multichannel sampling / Digitization

CAMERA MODULE

Camera Module & Chip Details

Camera Sensor ModuleModule circuit board and photosensitive chip
Metasurface Packaging on the Chip SurfaceA thin layer of microscopic metasurface structures is packaged on the chip surface for spectral control.

Camera module and chip photographs

16 channels

Physical Bands

Physical spectral response channels

120 channels

Reconstructed Bands

Up to 120 output bands

1 nm

Reconstructed Spectral Resolution

Down to 1 nm

10 ms

Minimum Sampling Interval

Time between consecutive samples

Wavelength Range380–1000 nm, covering visible and extended wavelengths
Physical Spectral Channels16 physical bands
Reconstructed OutputUp to 120 bands; reconstructed spectral resolution down to 1 nm
Temporal SamplingMinimum sampling interval: 10 ms
System IntegrationSpectral acquisition, imaging and reconstruction; packaging and interfaces selected for the solution

Specifications and conditions for achieving them simultaneously depend on model configuration and testing. 10 ms refers to the interval between consecutive samples.

Explore Visible Sensors ↗

02 / NEAR INFRARED

Near-Infrared Hyperspectral Sensor

Near-infrared and short-wave infrared research for material identification, spectral imaging and instrument integration. Channel configuration, response and imaging mode depend on the device design.

Coverage in Reference Documentation
1000–2400 nm
Representative Spectral Imaging Configuration
16 spectral channels
Documented Spatial Resolution
At least 2 megapixels

The handbook lists representative imaging capabilities. Packaging, interfaces and full response curves vary by model; the figures do not imply continuous spectral sampling or simultaneous configuration of every wavelength band.

Explore Near-Infrared Sensors ↗

RELATED RESEARCH / INFRARED SPECTROSCOPY

Infrared camera and relative spectral response curve
Infrared camera and relative spectral response curve

Metasurface Spectral Encoding × Uncooled Detection

Research in metasurface encoding, uncooled detection and computational reconstruction for compact infrared spectroscopy systems.

View Research Direction ↗

Uncooled metasurface infrared spectroscopy is a related research area; its wavelength range and performance are evaluated separately.

CONTACT

Technical Enquiries
& Collaboration.

Contact us for product selection, development
and project collaboration.

Get in Touch ↗
TECHNICAL COLLABORATIONBD@zhongkeyaoguang.com ↗

266 Fangzheng Avenue, High-tech Park, Liangjiang New Area, Chongqing, China

Zhongke Yaoguang (Chongqing) Optoelectronics Technology Co., Ltd.
PRIVACY

Privacy

This form prepares your message in your browser. Send Email opens your email application with BD@zhongkeyaoguang.com and your message prefilled. You must confirm sending in that application. This website does not send email from its server or store form entries. Downloading the enquiry brief saves a local file; it does not send a message. Unsaved entries are cleared when you close or refresh the page.

Do not include state secrets, confidential customer information or material you are not authorized to disclose. Technical files can be exchanged after communication and confidentiality arrangements are agreed.